And one thing about evaluating the level of noise at the workplace or any other situation, is to remember that the conventional rule of doubling (x 2) does not work here. - Frequency: 31.5...8000 Hz 0000002939 00000 n Type 3 sound level meters may be used for household applications, for example, for determining the level of noise. 0000001374 00000 n By touching the housing of the sound level meter, noise can be caused, which influences the measurement results. Thus, PCE-322A is ideal for real-time noise measurement as well as for long-term noise exposure monitoring over time. Since the latter have not been permanent and unchangeable, the measuring devices have gone through certain changes as well. An ISO calibration certificate can be acquired for most sound level meters offered by PCE Instruments. The sound pressure in the octave bands with these geometrical mean values is one of the parameters of the continuous noise that must be carefully controlled with the help of the sound measuring equipment. To minimize JavaScript is used on this site to improve user experience and enable functionality without JavaScript this site wont work as required. When the strength of the pressure fluctuations is increasing, we take it as the sound getting louder. For sure, the sound level meter used should be minimum class II and in calibrated condition, but mainly important is to avoid influences from the surrounding to receive repeatable and trustable results. - Measuring range: 26...130 dB  and residential environments. weighting Although typically used in laboratories and more advanced technical applications, a class 1 sound level meter usually divide the frequency spectrum into octaves and third bands. The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop. - 1/1 octave band included 0000001470 00000 n 2 year Warranty, PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. Since noise may be of different origin and come from different instruments and sources, a certain system was needed to be able to describe the character of each particular sound / noise and determine its compliance with the official regulations. Since the accuracies to be observed at different frequencies may differ, the accuracy cannot be specified with a fixed deviation number. The whole spectrum for convenience is divided into the octave bands, the noise pressure in which is measured by the noise analyzer. It is based on the 40 dB equal loudness curve. From £3,045.60 Inc. VAT/GST From £2,538.00 Ex. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. It must not be the same every day, but it is desirable that the 100% limit of the noise dose is not exceeded. Instead, a sound level data logger in the form of a USB stick can be used. - Class 2- Measuring range: 25 ... 136 db(A)- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN- Frequency weighting: A, B, C and Z- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)- adjustable data-recording interval from 1 s ... 24 h- 1/1 octave band filter (optional 1/3 octave band filter upgrade)- Kit includes type 2 / class 2 acoustic calibrator (PCE-SC 42). Since storage with subsequent evaluation requires a complex device or PC software, these memories can be found only in a higher-priced sound level meter. Therefore, the limits of noise exposure are not based on opinion, but on scientific fact. - Sound measuring range: 30 ...130 dB- Resolution: 0.1 dB- Accuracy: ±1.4 dB- Memory: Stores up to 32,700 readings- Sampling rate: 2 times per second It is a bit more complicated than just a traditional average calculation, since there are logarithms behind noise/sound level measurements, but nevertheless, it gives an exact information whether the noise level in a certain area or in the workplace is satisfactory or unacceptable. - 1/3 octave band optional measures and noise exposure estimation. slow time evaluation. Commonly referred to as a sound meter, noise meter, decibel meter, or sound pressure level meter, a sound level meter is designed to respond to sound in approximately the same way as the human ear. For a class 2 sound level meter, the deviation over the complete frequency spectrum may be slightly higher. Assessing a fluctuating noise level means getting a value for a level that is, in simple terms, the average level. To calibrate the meter, the microphone of the measuring instrument is inserted into the calibrator's chamber. 0000003582 00000 n VAT/GST Read more NoisePen Dosemeter - Personal Sound Exposure Meter Shoulder mounted noise dosemeter. The first thought might be that, of course, the other name for the maximum sound level is peak. The purpose of a sound level meter is to give objective, Depending on the source of noise and location the limit value for the sound pressure level within the octave band of a certain frequency rangy (mostly, from 63Hz to 8000Hz) will be different and it is calculated for each particular case individually. 0000005260 00000 n Peak relates more to sound pressure and it cannot be calculated using RMS. Throughout Europe, the Leq value is used as a measure for compliance with occupational health and safety regulations. They are also used for calibration of other sound level meters. Impulse (I) time weighing used in the past, had its place to be, but since the difference between the real-time sound level change and the Impulse measurement was very big (the decay after the real-time change was much longer that the reaction to the sound) and it was very asymmetric, the two, F and S, have been selected as preferable. The noise level meter is used for carrying out the measurements in the workplace of the workers exposed to noise continuously. Type 0 is referred to as the laboratory equipment, the measurements carried out with these devise are taken as reference for the other meters. 0000003119 00000 n - Incl. 0000005813 00000 n trailer << /Size 202 /Info 148 0 R /Root 163 0 R /Prev 1366811 /ID[<24ee6d3afd63eb267ff44fee2be70da8><24ee6d3afd63eb267ff44fee2be70da8>] >> startxref 0 %%EOF 163 0 obj << /Type /Catalog /Pages 150 0 R /Outlines 133 0 R /Threads 164 0 R /OpenAction [ 174 0 R /XYZ null null null ] /PageMode /UseNone /PageLabels << /Nums [ 17 << /St 18 /S /D >> ] >> /JT 161 0 R >> endobj 164 0 obj [ 165 0 R 166 0 R 167 0 R 168 0 R 169 0 R 170 0 R 171 0 R 172 0 R 173 0 R ] endobj 165 0 obj << /I << /Title (1\216)>> /F 17 0 R >> endobj 166 0 obj << /I << /Title (1/8\216)>> /F 18 0 R >> endobj 167 0 obj << /I << /Title (f)>> /F 76 0 R >> endobj 168 0 obj << /I << /Title (Background noise)>> /F 56 0 R >> endobj 169 0 obj << /I << /Title (Ideal white noise)>> /F 66 0 R >> endobj 170 0 obj << /I << /Title (\001)>> /F 2 0 R >> endobj 171 0 obj << /I << /Title (\n)>> /F 7 0 R >> endobj 172 0 obj << /I << /Title (+3dB/octave)>> /F 67 0 R >> endobj 173 0 obj << /I << /Title (63 125 250 500 1K 2K Hz)>> /F 68 0 R >> endobj 200 0 obj << /S 761 /O 983 /Filter /FlateDecode /Length 201 0 R >> stream Thus, the PCE-322A is an ideal real-time noise measuring device as well as being useful for long-term noise exposure monitoring over time. 0000009459 00000 n ISO Cal. small moisture particles. High humidity rates have influences on the quality of the microphone. In has been internationally accepted to take an 8-hour working day as standard and to calculate the daily maximum noise exposure dose in relation to 8-hour duration. The standard IEC 61672 (IEC 61672-1:2013, IEC 61672-2:2013, IEC 61672-3:2013 and etc.) Each country has its own numbers as for “healthy” norm, and this helps to regulate working process and keep the environment under control (regarding noise). Noise Measurement Terminology An Introduction Most noise measurement equipment is capable of measuring, recording and storing a wide range of parameters.